th  
Accessory
Actuator, Control Circuit, Cable for the motor(3m), Cable for the electromagnetic brake(3m), I/O Signals Connector, Connector for Regeneration Unit Input/Main Power Input Terminals, Connector for 24 VDC Power Supply Input/Regeneration Unit Thermal Input Terminals, Lever for wiring connector
Safety Standards
  
Product Name Lead Time Price (THB)
DG200R-ARMC2-377 Working Days 99,633.00 

●Production Information

Product to be discontinued (Order deadline, 31/Jan/2025)


●Component Name

DGM200R-ARMC(Actuator)
ARD-C(Control Circuit)

Specifications

Motor TypeαSTEP AR Series
Shaft TypeSingle Shaft
Output Table Supporting BearingCross-Roller Bearing
Frame Size200mm
Electromagnetic BrakeWith
Driver TypePulse Train Input
Repetitive Positioning Accuracy±15arcsec (±0.004°)
Lost Motion2arcmin (0.033°)
Permissible Torque50N・m
Inertial Moment J955280×10^-7kg・m^2
Permissible Speed110r/min
Gear Ratio18
Angular Transmission Error2arcmin (0.033°)
Permissible Thrust Load500N
Permissible Moment Load10N・m
Runout of Output Table Surface0.015mm
Runout of Output Table Inner (Outer) Diameter0.015mm
Parallelism of Output Table0.030mm
Actuator Degree of ProtectionIP20
Electromagnetic Brake Typepower off activated type
Electromagnetic Brake Power Supply Input VoltageDC24V±5% ※2
Electromagnetic Brake Power Supply Input Current0.25A
Speed and Positioning Control CommandPulse Train Input Type
Power Supply Input - VoltageSingle-Phase 200-230 VAC -15~+10%
Power Supply Input - Frequency50/60Hz
Power Supply Input - Current4.1A
Power Supply Input - Control Power SupplyDC24V±5% 0.75A ※2
Mass: Actuator10kg
Mass: Control Circuit0.75kg
  • Minimum movement of the output table(Factory setting):0.02deg/STEP
    Motor Resolution:1000P/R *1
    Holding Torque at Motor Standstill Power ON:20N・m
    Holding Torque at Motor Standstill Electromagnetic Brake):20N・m
  • ∗ UL/CSA/CE mark only apply to this circuit part.
  • *1 Motor resolution at the time of shipping. For how to calculate the minimum movement [ ˚] of the output table with the gear ratio of 18, see [Other specifications].
    *2 For the pulse train input type, a separate power supply for the electromagnetic brakes is required for the electromagnetic brake type.
    If the wiring distance between the motor and driver is extended to 20 m min. using an accessory cable (sold separately), the 24 VDC±4% specification applies.
    ●Depending on the driving conditions, a considerable amount of heat may be generated by the motor. Be sure to keep the motor case temperature at 100˚C or less.
    ●The repetitive positioning accuracy is measured at a constant temperature (normal temperature) under a constant load.
    ●IP20 for motor connector

Download

The link of Web2CAD site can be used for 3D CAD data downloading as well. For more details, please click here.

Operating Manual Motorized actuator Hollow rotary actuator Function Setting EditionHL-80019E.pdf