th  
Accessory
Motor, Gearhead, Control Circuit, Conversion Cable, Connection Cable(2m), CN1 Connector, CN5 Connector, CN7 Connector, Driver Mounting Bracket (with screws), Installation Screws, Parallel Key, Operating Manual
Safety Standards
  
Product Name Lead Time Price (THB)
BXS460AM-30S-2Please contact us for more infoPlease contact us for more info

You cannot add this product to a cart. Sorry for your inconvenience but please contact to customer support centre.

●Production Information

Discontinued product in 31/Mar./2022


●Component Name

BXM460M-GFS(Motor)
GFS4G30(Gearhead)
BXSD60-A(Control Circuit)

Specifications

Frame Size80mm
Shaft/Gear TypeCombination Type Parallel Shaft Gearhead
Gear Ratio30
Electromagnetic BrakeWith
Included Cable2m
Rated Output Power60W
Power Supply Input Rated VoltageSingle-Phase 100-120VAC
Power Supply Input Permissible Voltage Range-15~+10%
Power Supply Input Rated Frequency50/60Hz
Power Supply Input Permissible Voltage Range±5%
Power Supply Input Rated Input Current2.2A
Power Supply Input Maximum Input Current5.5A
Rated Torque (Motor Shaft)0.2N・m
Starting Torque (Motor Shaft)0.4N・m
Rated Speed (Motor Shaft)3000r/min
Speed Control RangeDigital setting:0.07-133r/min
Permissible TorqueDigital setting:
5.2N・m(0.07-100r/min)
3.9N・m(133r/min)
Permissible Load Inertia J800×10^-4kg・m^2
Permissible Load Inertia J (When instantaneous stop or instantaneous bi-directional operation is performed)198×10^-4kg・m^2
Rotor Inertia J0.24×10^-4kg・m^2
Speed Regulation (Load)±0.05% or less: Conditions 0 ~ rated torque, rated speed, rated voltage, normal temperature
Speed Regulation (Voltage)±0.05% or less: Conditions Rated voltage −15~+10%, rated speed, no load, normal temperature
Speed Regulation (Temperature)±0.05% or less: Conditions Ambient temperature 0~+50℃, at rated speed, with no load, at rated voltage(Digital setting)
Continuous Regenerative Power100W
Instantaneous Regenerative Power240W
Applicable Regeneration UnitEPRC-400P *1
Electromagnetic Brake TypePower off activated type *2
Electromagnetic Brake Static Friction Brake0.2N・m
StandardUL、CSA
CE Markingaffixed
Speed Setting MethodSet in either of the following methods.
・Operating Panel ・MEXE02✽ ・OPX-2A (Accessory)
✽ The Data Setting Software MEXE02 can be downloaded from the website. When using MEXE02, the data setting software communication cable CC05IF-USB (accessory) is required.
Acceleration Time / Deceleration Time0.000~30.00 s (Rated speed, no load running)
Protective FunctionWhen the following protective functions operate, the ALM output is turned off, and the motor is stopped. At the same time, the alarm code is indicated in the operating panel.Overfl ow, overcurrent, overvoltage, undervoltage, overload, overspeed, EEPROM failure, initial sensor failure, initial operation inhibited, overheating of regeneration unit, software overtravel, operating data problem
Max. Extension DistanceMotor and Driver Distance: 30 m (Accessory connection cable used)
Time RatingContinuous
Mass: Motor2.5kg
Mass: Control Circuit0.8kg
  • ✽1 Specification for products with electromagnetic brake
    Do not start or stop the motor by turning the power supply ON/OFF, as it will cause abnormal wear to the electromagnetic brake.
    ✽2 Value when a regeneration unit is used.
    Install the regeneration unit at a location that has the same heat radiation capability as an aluminum heat sink that is 350×350 mm and 3 mm thick.

Download

The link of Web2CAD site can be used for 3D CAD data downloading as well. For more details, please click here.

2D-CAD Combination Type MotorC154B.dxf
Control CircuitC259.dxf
3D-CAD Combination Type MotorC154B.step
Control CircuitC259.step
3D-CAD(web2CAD) Motor / Gearheadto web2CAD site
Control Circuitto web2CAD site
Catalogue Brushless Motor and Driver Packages BXII SeriesBXII_Series_a.pdf
Operating Manual Brushless Motor and Driver Package BXII Series USER MANUALHM-5142E.pdf
Data Setter OPX-2A OPERATING MANUAL Before UseHM-40142E.pdf
Data setter OPX-2A OPERATING MANUAL BXII SeriesHP-5058E.pdf