Cables: For AZ Series AC Input Network Compatible

Cables: For AZ Series AC Input Network Compatible
*1
Flexible connection cables and flexible extension cables with excellent bending resistance are also available.
*2
Required for electromagnetic brake motors.
*3
Not supplied.
*4
When using a MECHATROLINK-III compatible driver or a SSCNET III/H compatible driver, please use the general-purpose type.

Note

  • Up to 3 cables can be used for connection between the motor and driver.
  • The maximum extension distance between the motor and driver is 20 m.

Connection Cable

This cable can be used to connect the motor with driver.
The motor cable and electromagnetic brake cable from the motor cannot be connected directly to the driver.
When connecting to a driver, use a connection cable.

[2] Extension Cable Set Motor Side/Flexible Extension Cable Set Motor Side

  • For Motor
    Extension Cables for Motors
  • For Encoder
    Extension Cables for Encoders
  • For Electromagnetic Brake *
    Extension Cables for Electromagnetic Brakes
  • *Required for electromagnetic brake motors.

Note on Use of Flexible Cables

Other Cables

[3] I/O Signal Cable

This cable can be used to connect the driver and host control device.

Connector Type

  • Multi-core shielded cable
  • Single-ended discrete wire
  • Includes ground wire with round terminal for easy shield grounding
Product Name Applicable Drivers Length
(m)
Number of Cores AWG Finished Outer Diameter
I/O signal cable (connector included)
CC24D005C-1 Built-in positioning function type
Pulse input type with RS-485 communication
Pulse input type
EtherNet/IP compatible*
EtherCAT compatible*
PROFINET compatible*
0.5 24 24 φ9.5
CC24D010C-1 1
CC24D020C-1 2
  • *Cannot be connected to drivers with DC input. Use a general-purpose type I/O signal cable.

General-Purpose Type

  • Multi-core shielded cable
  • Double-ended discrete wire
  • Includes ground wire with round terminal for easy shield grounding
  • Select the number of lead wire cores that matches the desired functionality.
Product Name Length
(m)
Number of Cores AWG Insulator Outer Diameter Finished Outer Diameter
I/O signal cable (general-purpose type)
CC06D005B-1 0.5 6 24 φ1.1 φ5.4
CC06D010B-1 1
CC06D015B-1 1.5
CC06D020B-1 2
CC10D005B-1 0.5 10 φ6.7
CC10D010B-1 1
CC10D015B-1 1.5
CC10D020B-1 2
CC12D005B-1 0.5 12 φ7.5
CC12D010B-1 1
CC12D015B-1 1.5
CC12D020B-1 2
CC16D005B-1 0.5 16
CC16D010B-1 1
CC16D015B-1 1.5
CC16D020B-1 2

[4] AC Power Supply Cable

This cable is to connect driver and AC power supply. Cables are available with or without a power supply plug.

Product Name Length
(m)
Product Line Power Supply Voltage
AC power supply cable
CC01AC03P 1 Plug included Single-Phase 100-120 VAC
CC02AC03P 2
CC03AC03P 3
AC power supply cable
CC01AC03N 1 Plug not included Single-Phase 100-120 VAC
Single-Phase 200-240 VAC
CC02AC03N 2
CC03AC03N 3
AC power supply cable
CC01AC04N 1 Three-Phase 200-240 VAC
CC02AC04N 2
CC03AC04N 3

[5] DC Power Supply Cable

Shielded cable for connection of DC power supply and electromagnetic brake. Ground wire with round terminal for easy shield grounding.

Product Name Length
(m)
AWG Insulator Outer Diameter Finished Outer Diameter
DC power supply cable
CC02D005-3 0.5 20 φ1.65 φ5.9
CC02D010-3 1
CC02D015-3 1.5
CC02D020-3 2
CC02D050-3 5

Cable Note When Wiring Flexible Cable

Do not bend the cable at the connector. Stress applied to the connectors and terminals causes poor contact and disconnection.

How to Fix the Cable

Fix the connector part in 2 places to prevent it from moving.

Fix the connector part in 2 places to prevent it from moving.

Wiring Length and Bending Radius of the Cable

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.
In addition, the bending radius (R) should be 6 times the cable diameter min.

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.

Interference of the Cable

Wire the cables in the cable holder without bringing them into contact with each other. This will add stress to the cable, and cause it to break prematurely. Please check note on cable holders carefully before use.

Cable Kinks

◇Please wire without kinks in the cable. Kinking in a twisted state can cause premature disconnection. After wiring, confirm that there are no kinks in the cable, using the print on the cable surface as a reference.