Reversible Motors KII Series (New standard)
3RK15A-JC

Motor
การจำแนกประเภทผลิตภัณฑ์ | ชื่อผลิตภัณฑ์ | รายการราคา | วันที่จัดส่ง |
---|---|---|---|
Motor | 3RK15A-JC | THB 2,653 | 22 Working Days |
รวม
- Motor: Capacitor, Capacitor Cap
ข้อมูลเฉพาะ
ดาวน์โหลดข้อมูล
ข้อมูลเฉพาะอื่น ๆ
General Specifications
Item | Specifications |
---|---|
Insulation Resistance | 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after 30 minutes continuous operation under normal ambient temperature and humidity. |
Dielectric Strength | Sufficient to withstand 1.5 kVAC at 50 Hz or 60 Hz applied between the motor windings and the case for 1 minute after 30 minutes continuous operation under normal ambient temperature and humidity. |
Temperature Rise | After 30 minutes of continuous operation at normal ambient temperature and humidity with the gearhead or equivalent heat sink* connected to the motor, the winding temperature rise value measured using the resistance change method will be 80 °C max. |
Thermal Class | 130 (B) |
Overheat Protective Device | The 6 W type is impedance protected Other types: Built-in thermal protector (Automatic return type) Open: 130 ± 5 °C, Return: 85 ± 20 °C |
Operating Ambient Temperature | Single-Phase 100 V, Single-Phase 200 V: -10~+50 °C (Non-freezing) Other voltages: -10~+40 °C (Non-freezing) For gearhead gear ratios 2 or 3 the lower temperature limit is 0 °C. |
Operating Ambient Humidity | 85 % max. (Non-condensing) |
Degree of Protection |
Terminal box type:
IP40 (25 W, 40 W)
IP20 (60 W, 90 W) Lead wire type:
IP20
|
- * Heat Sink Size (Material: Aluminum)
Motor Type (Output power) | Size (mm) | Thickness (mm) |
---|---|---|
6 W Type | 115 x 115 | 5 |
15 W Type | 125 x 125 | |
25 W Type | 135 x 135 | |
40 W Type | 165 x 165 | |
60 W, 90 W Type | 200 x 200 |
Permissible Radial Load and Permissible Axial Load of Round Shaft
Product Name | Permissible Radial Load N | Permissible Axial Load | |
---|---|---|---|
Distance From the End of the Motor Output Shaft | |||
10 mm | 20 mm | ||
2IK6 2RK6 |
50 | 110 | Half of the motor mass or less* |
3IK15 3RK15 |
40 | 60 | |
4IK25 4RK25 |
90 | 140 | |
5IK40 5RK40 |
140 | 200 | |
5IK60 5IK90 5RK60 5RK90 |
240 | 270 |
- * Avoid applying axial loads as much as possible.
If an axial load is unavoidable, keep it at half or less of the motor mass.

มาตรฐาน
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with safety standards for each of our product models can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
การกำหนดค่าระบบ
สายเคเบิลและอุปกรณ์เสริม
close

close

close